RENCANA ANGGARAN BIAYA KEGIATAN PEKERJAAN LOKASI PROVINSI
: : : :
PEMANTAUAN KUALITAS LINGKUNGAN
Pembangunan Instalasi Pengolah Air Limbah (IPAL) Medik untuk Puskesmas Rawat lnap PUSKESMAS NEGARA KECAMATAN DAHA UTARA KAB. HSS KALIMANTAN SELATAN
No.
Uraian Pekerjaan
1
2
I. 1. 2. 4. 5.
PEKERJAAN PERSIAPAN Pembersihan Lokasi Pengukuran Papan Nama Proyek Pemasangan Bowplank
II. 1. 2.
PEKERJAAN TANAH DAN PASIR Pek. Galian Tanah Pek. Urugan Pasir Bawah Pondasi Poer
No. Analisa dan Satuan 3
-
Volume Harga Satuan (Rp) Jumlah Harga (Rp) 4
Unit M2 Bh Unit
5
1.000 1.000 1.000 1.000 SUB TOTAL
1 3
M3 M3
4.050 0.825 SUB TOTAL
III. 1.
2.
PEKERJAAN LANTAI DUDUKAN REAKTOR Pek. Beton Bertulang 1 : 2 : 3 - Kolom 30/30 - Balok Lantai 30/30 - Pondasi Poer - Plat Lantai tebal 12 cm Pek. Pancangan Galam Dia. 10 mm Panjang 4 m
10 10 10 8 -
M3 M3 M3 M3 Pot
0.810 2.610 1.800 4.080 54.000 SUB TOTAL
IV. 1.
2.
PEKERJAAN EQUALIZING TANK Pek. Beton Bertulang 1 : 2 : 3 - Dinding Beton Bertulang Tebal 15/15 - Lantai Beton Bertulang Tebal 15/15 Pek. Pancangan Galam Dia. 10 mm Panjang 2 m
8 8 -
M3 M3 Pot
2.250 0.338 25.000 SUB TOTAL
6
No.
Uraian Pekerjaan
1
2
V
PENGADAAN REAKTOR IPAL KAPASITAS 8,0 M³/H SPESIFIKASI OXIDATOR GENERATOR UNIT 1. Box Shield : 1500mmX800mmX900mm Dimension : Mild steel Material Coating Powder Coating 2. Oxidator Generator BART O2 Oksigen Flow rate Oxidator concentration Oxidator output Power cooling Ambient temperature maks Fitting Size : 1. Inner Diameter 2. Outer Diameter Output Frequency Mounting holes foot print of power supply Dew Point
Working condition 3. Supply Oxidator
4. Ventury
5. Cooling system
Adjustable range Ox tube dimension Power Supply Dimension Oxidator generator tube weight Power supply weight ⁰ Tubing Ambient temperature maksimum 35 C , air cooled BART O2 Genarator Oksigen output Oksigen concentration Power Pressure (inlet) Pressure (outlet) Relative Humidity Noise Rate speed BART VENT 0503 material PVDF water flow rate inlet and outlet flexible hose length Fan Cooling Power Forced condenser air cooling system
Spesifikasi dan Satuan 3 -
Volume Harga Satuan (Rp) Jumlah Harga (Rp) 4 Unit
2 1-5 28 - 65 3.9 - 5.04 0.05 Air Cooled 35.0
unit L/min Mg/L g/hr kW ⁰
7.0 11.0 42,186.0 190.5 x 75 (45.0)
mm mm ⁰Khz mm C
20 - 100 250x105x125 200 x 75 x 83 0.53 1.2 PTFE 2 3.0 40 - 93 0.3 0.18 - 0.2 0.06 - 0.08 ≤ 85% ≤ 55 1,400 2
C
% mm mm kg kg
unit L/min % kW Mpa Mpa Db rpm unit
up to 1 ton / hr 1/2" 1/4" 100 mm 0.125 kW
1.000
5
6
No.
Uraian Pekerjaan
1
2
1. Pipeline
REACTOR TOWER Stainless Steel SUS 304 grade 8% Dimension High Diameter minimal Quantity Flow meter in line type Odour removal upper location With frame made of UNP 100 Mild steel and others CIRCULATION PUMP SYSTEM Power Quantity ON/OFF with WLC system Power Quantity DISTRUCTED OXIDATOR SYSTEM Capacity Quantity FILTERING SYSTEM Material Capacity SHIELDING ALL SYSTEM Mild steel square pipe Wall high 1000 mm made of Plate mild steel Finishing Powder coating Dimension all 2400x2400x3200 EQUALIZER DAN OUTLET PVC AW
2. Outlet
Control Pond
1. Material
1. Intake Pump
2. Circulation Pump
1. UV Filtering
1. Filter Tank
1. Frame
Spesifikasi dan Satuan 3
1,600 382.0 2 2 Carbon
Volume Harga Satuan (Rp) Jumlah Harga (Rp) 4
5
mm mm unit unit
0.2 kW 2 set 0.3 kW 2 set 8 GPM 2 Set FRP 10" 4 m3/h
1 lot
SUB TOTAL
6