Oil/Water Monitors
Models 4528EZ & 4728 Monitors Model CX-645 Probe Bulletin SSIS005
The INVALCO Model 4728 S&W Monitor, in conjunction with a Model 4528EZ Detector and a Model CX-645 Capacitance Probe is a continuous on-line monitor of percent water in a flowing crude oil emulsion stream. This unit displays percent of water in various ranges from 0-5% up to and including 0-20% on a digital LCD indicator. In addition, the Model 4728 provides a 4-20 mA analog output proportional to input range, and a fieldadjusted, time-delayed, limit relay for valve control or alarming. The Model 4728 utilizes CMOS circuitry for low power consumption, high reliability, and wide temperature stability.
Features Real-Time Display and Retransmission of S&W - Allows quick response to upset conditions for downstream controls. Adjustable Delay of Relay Closure - Prevents nuisance alarms and “actuator overload”. Direct Analog Output from Model 4528EZ Detector - A 4-20 mA signal is standard from the probe without the need to include the Model 4728 monitor. NACE Adaptable - Can be modified for use in sour service.
Applications LACT (Lease Automatic Custody Transfer) Units Detect and reroute oil that has been contaminated by excess S&W. Pipeline Loading Monitor transfer of petroleum/condensate products from offshore loading facilities. Dehydration Equipment Determine and enhance equipment efficiencies. Fuel Oil Monitoring Determine contamination of fuel oil by condensation or other external factors before entry to engine. Storage and Treating Facilities Monitoring and early detection of undesirable conditions as well as interface detection during de-watering of storage tanks.
Model 4728 Specifications
Model 4728 Monitor and Model CX-645 Probe
Display Four digit LCD with decimal point. Analog Outputs 4-20 mA, 2-wire internally powered or 4-20 mA, 3-wire externally powered. Relay Output SPDT Relay, 10A, 250 Vac. 1/2 Hp 250 Vac, 10A - 120 Vac resistive. 1/3 Hp 120 Vac, 10A - 30 Vdc resistive. Time Delay 0 to 90 seconds adjustable in 10 second increments. Off-delay approximately 10% of on-delay time. Temperature Range -20°F to 160°F (-20°C to 70°C). Enclosures NEMA 4X, weatherproof. NEMA 7, explosion-proof, Class I, Division 1, Groups C and D.
Power Supply 18-28 Vdc @ 130 mA 115/220 Vac S&W Range 0-5%, 0-10%, and 0-20% range options.
FMC INVALCO
!
Fluid Control
!
Stephenville, Texas 76401
!
Telephone: 254/968-2181
!
FAX 254/968-5709
!
Toll Free: 800/468-2526
Model 4728 Ordering Information
Model 4728 Dimensional Specifications Inches (mm)
Note: Dimensions - Inches to the nearest tenth (millimeters to the nearest whole mm), each independently dimensioned from respective engineering drawings.
Model 4528EZ Detector and Model CX-645 Probe The Model 4528EZ Detector and Model CX-645 Probe provide a direct analog (0-5 Vdc and 4-20 mA) output of percent emulsified water (as S&W) in the process stream. This signal is designed to be used externally by the Model 4728 monitor or other control devices such as PLC’s or Remote Terminal Systems. The probe is constructed of two concentric tubes. Wetted surfaces are coated with a baked-on phenolic two-part epoxy. The inner tube is insulated from the outer tube by Teflon spacers and is electrically connected to a terminal
within the sensor housing. The internal element spacers can be fitted with trimmer rods should it be necessary to adjust the base capacitance. The detector operates from a 8-28 Vdc regulated power supply from within the associated monitor or customersupplied source. All calibration and adjustments can be accessed through the front for ease of use. The Model 4528EZ detector offers the flexibility of a high or low fail-safe. This fail-safe feature guarantees the quality of the output signal from the detector chassis and will sense over- and under-range conditions as well as an open or shorted probe.
Model CX-645 Capacitance Probe & Model 4528EZ Detector
Model CX-645 Capacitance Probe & Model 4528EZ Detector
Detector/Probe Specifications Power Supply 8-28 Vdc @ 130 mA
Process Connections ANSI RF or RTJ Flanges to 600# (all sizes) (others by special order). Threaded MNPT or Grooved (2” and 3”).
S&W Range Field Selectable 0-5%, 0-10%, and 0-20%.
Pressure Ratings As per Flange selection, 1440 psig max. (Others by special order) NPT - 1440 psig max. Victualic grooved - 350 psig
Measurement Accuracy ±1.0% of full scale. Resolution/Sensitivity ±0.5% of full scale.
Temperature Range -20°F to 180°F standard. -20°F to 375°F optional. Approvals UL/C-UL Explosion-proof certificate for Class I, Div. 1, Groups C and D or Class II, Groups E, F, and G hazardous locations.
Probe Material A53 GrB Carbon Steel is standard. Stainless Steel available. Probe Finish Baked-on phenolic two-part epoxy. Probe Sizes/Length 2” I.D. is 17” face-to-face. 3” to 12” I.D. sizes are 32” face-to-face.
Dimensions - CX-645 Specifications Inches (mm) 1.25” FNPT Conduit Connection Model 4528EZ Exp. Housing Dimension “B” Element (Inner Plate)
Teflon Insulator
*-20°F to 180°F dimension given. For -20°F to 375°F dimension add 6.4”.
Trimmer Rod (if needed)
Probe Body (Outer Plate) Dimension “A”
Note: Dimensions - Inches to the nearest tenth (millimeters to the nearest whole mm), each independently dimensioned from respective engineering drawings.
Typical Applications Model 4728 Oil/Water Monitor
Capacitance Probe Model CX-645 & 4528EZ Detector Four Conductor Cable
Capacitance Probe Model CX-645 & 4528EZ Detector
Model 4728 Oil/Water Monitor
Four Conductor Cable
Analog Output
Analog Output
Recorder, PLC/DCS System Solenoid Diverter Valve
Percent Water Indication and Set-Point Control In this application the adjustable alarm may be used to operate a diverter valve should the water content exceed a preset percentage. Local indication is provided and an analog output for other indication or control functions is available.
Percent Water Recording In this application the Model 4728 provides local reading on an LCD display and provides an analog output (4-20 mA) to a standard recorder, PLC, or DCS System. This configuration is used to monitor and control Separator and Heater-Treater efficiencies as well as other oil field and industrial applications.
CX-645 Capacitance Probe Ordering Information BS&W Probe, Ranges from 0-20% water - to be used with Model 4528EZ Detector CX-645
PROBE MATERIAL: Carbon Steel
l CODE PROBE BODY SIZE l 2 l 2 INCH I.D. x 17" FACE TO FACE 3 l 3 INCH I.D. x 32" FACE TO FACE 4 l 4 INCH I.D. x 32" FACE TO FACE 6 l 6 INCH I.D. x 32" FACE TO FACE 8 l 8 INCH I.D. x 32" FACE TO FACE 10 l 10 INCH I.D. x 32" FACE TO FACE CODE END CONNECTIONS l l 00 l l SCREWED ENDS (to 3" only) 00 l l GROOVED ENDS/Victaulic (to 4" only) 00 l l 150 LB ANSI RAISED FACE 30 l l 300 LB ANSI RAISED FACE 60 l l 600 LB ANSI RAISED FACE (SCH 80) (FOR 8" AND 10") 90 l l 900 LB ANSI RAISED FACE and RING T (SCH 160) (10") 05 l l 150 LB ANSI RTJ 35 l l 300 LB ANSI RTJ 65 l l 600 LB ANSI RTJ (SCH 80) (FOR 8" AND 10") 95 l l 900 LB ANSI RTJ (SCH 80) 115 l l 1500 LB ANSI RTJ (SCH 160) CODE MATERIAL AND TEMPERATURE OPTIONS l l l B l l l STANDARD MATERIALS, A53B CARBON STEEL, -20-180° F H l l l STANDARD MATERIALS/HIGH TEMP, -20 - 375° F S l l l 316 STAINLESS STEEL MATERIALS, -20-180F T l l l 316 STAINLESS STEEL/HIGH TEMP, -20 -375°F CODE CONNECTION STYLE l l l l S l l l l SCREWED CONNECTIONS, MNPT G l l l l VICTAULIC CONNECTIONS (GROOVED) F l l l l FLANGED CONNECTIONS CODE OPEN l l l l l P l l l l l PHENOLIC COATING ( Interior ) l l l l l l Example: l l l l l CX - 645 3 60 B F P = CX-645-360-BFP Choose one code selection from each option group to build model number.
www.fmcinvalco.com The specifications contained herein are subject to change without notice and any of said specifications should from the manufacturer that the specifications are currently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect. FMC INVALCO Fluid Control Stephenville, TX 76401, Phone: 254/968-2181, FAX: 254/968-5709, Toll Free: 800/468-2526 Printed in U.S.A. © 6/05 FMC INVALCO All rights reserved. 4 • SSIT042
Issue/Rev. 0.1 (2/04)
Temperature Compensated Water Cut Monitor
Energy Systems
Model WCM 7300 Bulletin SSIS003
The Model WCM 7300 is designed to provide the highest possible sensitivity, resolution, and accuracy for water content determination in crude oil, other hydrocarbons, or other low dielectric liquids from a max of 25% to levels below 1000 parts per million (ppm). In oil and natural gas (condensate) production, water cut and S&W measurements are significantly improved with the WCM 7300 technology. Enhanced digital signal processing and full product temperature compensation are two of the technological advancements utilized by this device. Probe sizes from 2” through 12” are available. 4-20 mA and 0-5 volt outputs are available for remote readout. Water cut, process temperature or probe electrical value can be selected for viewing without removing condulet cover by use of a supplied magnet to operate an internal reed switch.
Product Temperature Compensation The base dielectric constant (Dk) of oils can change with changes in temperature. This can cause traditional monitors to change without a variance in water content. For example; for a 10°F change, a typical curde oil may show a reading shift of as much as 0.1%, which normally would be considered as water. The WCM 7300 measures product temperature and calculates a corrected cut reading, providing a true water or S&W cut at any temperature up to 160°F.
Features NACE Adaptable - Can be modified for use in sour service.
Applications LACT (Lease Automatic Custody Transfer) Units Detect and provide relay closure that can be used to reroute oil that has excess S&W. Pipeline Loading Monitor transfer of petroleum/condensate products from loading facilities. Dehydration Equipment Determine and enhance equipment efficiencies, by monitoring the product and indicating water content. Fuel Oil Monitoring Determine contamination of fuel oil by condensation, or other external factors, before entry to engine. Storage and Treating Facilities Monitoring and early detection of undesirable conditions as well as interface detection during de-watering of storage tanks.
FMC INVALCO 2526
!
Fluid Control
!
Stephenville, Texas 76401
!
WCM 7300 Water Cut Monitor
Measurement/Monitor Specifications Power Supply 20-30 Vdc +/-10% @ nominal, 100 mA max. S&W Full Scale Range 0-25% Field adjustable to 0-5%, 0-10%, etc. Accuracy Is defined as the variance observed between the 7300 reading and the water grindout of the oil. Normal variances are: +/-.05 from 0 to 5% water +/-.1 from 5 to 10% water +/-.15 from 10% to 15% water +/-.2 to .25 from 15 to 25% water Displays One line 16 character, alphanumeric LCD showing by selection: Water Cut Process Temperature Probe Electrical Value Red/Green LED showing good oil, bad oil, or by ing, condition. Pressure Ratings As per Flange selection, 1440 psig max. (Others by special order) NPT - 1440 psig max. Victualic grooved - 350 psig
Telephone: 254/968-2181
!
FAX 254/968-5709
!
Toll Free: 800/468-
WCM 7300 Dimensions Inches (mm)
Note: Dimensions - Inches to the nearest tenth (millimeters to the nearest whole mm), each independently dimensioned from respective engineering drawings.
WCM 7300 Probe/Monitor Assemblies Ordering Information WCM 7300 l l l l l l l
WATER CUT MONITOR, DIGITAL, TEMPERATURE COMPENSATING, Ranges from 0-20% water PROBE MATERIAL: Carbon Steel CODE PROBE BODY SIZE 2 3 4 6 8
2 INCH I.D. x 3 INCH I.D. x 4 INCH I.D. x 6 INCH I.D. x 8 INCH I.D. x
17" FACE TO FACE 32" FACE TO FACE 32" FACE TO FACE 32" FACE TO FACE 32" FACE TO FACE
CODE END CONNECTIONS
l l l l l l l l l l l l
l l l l l l l l l l l l
l l l l l
l l l l l
l l l l l
l l l l
l l l l
l l l l
00 00 00 30 60 90 05 35 65 95 115
SCREWED ENDS (to 3" only) GROOVED ENDS/Victaulic (to 4" only) 150 LB ANSI RAISED FACE 300 LB ANSI RAISED FACE 600 LB ANSI RAISED FACE (SCH 80) (FOR 8" AND 10") 900 LB ANSI RAISED FACE and RING T (SCH 160) (FOR 10") 150 LB ANSI RTJ 300 LB ANSI RTJ 600 LB ANSI RTJ (SCH 80) (FOR 8" AND 10") 900 LB ANSI RTJ (SCH 80) 1500 LB ANSI RTJ (SCH 160) CODE MATERIAL AND TEMPERATURE OPTIONS B H S T l l l l
STANDARD MATERIALS, A53B CARBON STEEL, -20-160F STANDARD MATERIALS/HIGH TEMP, -20 - 375F 1 316 STAINLESS STEEL MATERIALS -20-160F 316 STAINLESS STEEL/HIGH TEMP, -20 - 375F 1 CODE CONNECTION STYLE S G F
SCREWED CONNECTIONS, MNPT VICTAULIC CONNECTIONS (GROOVED) FLANGED CONNECTIONS CODE OPEN
l l l l l P l l l l l Epoxy l l l l l l Example: l l l l l WCM7300 4 60 B F P = WCM7300 - 460 - BFP Choose one code selection from each option group to build model number and correct pricing.
Notes: 1 - Consult factory for temperature compensation
www.fmcinvalco.com The specifications contained herein are subject to change without notice and any of said specifications should from the manufacturer that the specifications are currently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect. FMC INVALCO Fluid Control Stephenville, TX 76401, Phone: 254/968-2181, FAX: 254/968-5709, Toll Free: 800/468-2526 Printed in U.S.A. © 6/05 FMC INVALCO All rights reserved. 6 • SSIT042
Issue/Rev. 0.1 (2/04)
Temperature Compensated Water Cut Monitor with Insertion Probe
Energy Systems
Model WCM 7300E Bulletin SSIS004
The Model WCM 7300E is designed to provide the highest possible sensitivity, resolution, and accuracy for water content determination in crude oil, other hydrocarbons, or other low dielectric liquids from a max of 25% to levels below 1000 parts per million (ppm). In oil and natural gas (condensate) production, water cut and S&W measurements are significantly improved with the WCM 7300E technology. Enhanced digital signal processing and full product temperature compensation are two of the technological advancements utilized by this device. Water cut, process temperature or probe electrical value can be selected for viewing without removing condulet cover by use of a supplied magnet to operate an internal reed switch.
Product Temperature Compensation The base dielectric constant (Dk) of oils can change with changes in temperature. This can cause traditional monitors to change without a variance in water content. For example; for a 10°F change, a typical curde oil may show a reading shift of as much as 0.1%, which normally would be considered as water. The WCM 7300 measures product temperature and calculates a corrected cut reading, providing a true water or S&W cut at any temperature up to 160°F.
Applications LACT (Lease Automatic Custody Transfer) Units Detect and provide relay closure that can be used to reroute oil that has excess S&W. Pipeline Loading Monitor transfer of petroleum/condensate products from loading facilities. Dehydration Equipment Determine and enhance equipment efficiencies, by monitoring the product and indicating water content. Fuel Oil Monitoring Determine contamination of fuel oil by condensation, or other external factors, before entry to engine. Storage and Treating Facilities Monitoring and early detection of undesirable conditions as well as interface detection during de-watering of storage tanks.
Features Nace Adaptable - Can be modified for use in sour service.
FMC INVALCO
!
Fluid Control
!
Stephenville, Texas 76401
!
WCM 7300E Water Cut Monitor
Measurement/Monitor Specifications Power Supply 20-30 Vdc +/-10% @ nominal, 100 mA max. S&W Full Scale Range 0-25% Field adjustable to 0-5%, 0-10%, etc. Sensitivity/Resolution .01% - 100 ppm Accuracy Is defined as the normal variance observed in the field between the 7300 reading and the water grindout of the oil. These observed variance numbers are larger than the stated sensitivity/resolution of the WCM because the Dk of the oil in actual field operations is not constant but is continuously changing due to varying amounts of trace contaminents such as chemicals, minerals, solution gas, etc. These cause small changes in the Dk which is independent of the water cut. The WCM “sees” these changes and so indicates them. In the laboratory the WCM easily detects and indicates changes of 100 ppm, or less. This accuracy is seldom observed in the field because of the reasons stated above. The accuracy statements shown are what is normally obtainable (based on many, many installations) in the field and not on controlled testing in a lab. Normal variances are: +/-.05 from 0 to 5% water +/-.1 from 5 to 10% water +/-.15 from 10% to 15% water +/-.2 to .25 from 15 to 25% water
Telephone: 254/968-2181
!
FAX 254/968-5709
!
Toll Free: 800/468-2526
Measurement/Monitor Specifications Pressure Ratings As per Flange selection, 1440 psig max. (Others by special order) NPT - 1440 psig max. Victualic grooved - 350 psig
Displays One line 16 character, alphanumeric LCD showing by selection: Water Cut Process Temperature Probe Electrical Value Red/Green LED showing good oil, bad oil, or by ing, condition.
Ordering Information WCM
INSERTION STYLE WATER CUT MONITOR, DIGITAL, TEMPERATURE COMPENSATING, Ranges from 0-20% water
7300E
PROBE MATERIAL: Carbon Steel CODE PROBE BODY SIZE
l l
2
2 INCH O.D.
l
3
l
l
3 INCH O.D. CODE END CONNECTIONS
l
l
00
l
l
00
150 LB ANSI RAISED FACE
l
l
30
300 LB ANSI RAISED FACE
SCREWED ENDS
l
l
60
600 LB ANSI RAISED FACE
l
l
90
900 LB ANSI RAISED FACE(SCH 80)
l
l
05
150 LB ANSI RTJ
l
l
35
300 LB ANSI RTJ
l
l
65
600 LB ANSI RTJ
l
l
95
900 LB ANSI RTJ (SCH 80) 1500 LB ANSI RTJ (SCH 160) CODE MATERIAL AND TEMPERATURE OPTIONS
l
l
115
l
l
l
l
l
l
B
STANDARD MATERIALS, A53B CARBON STEEL, -20-160F STANDARD MATERIALS/HIGH TEMP, -20 - 375F 1
l
l
l
H
l
l
l
S
316 STAINLESS STEEL MATERIALS -20-160F
l
l
l
T
l
l
l
l
316 STAINLESS STEEL/HIGH TEMP, -20 - 375F CODE CONNECTION STYLE
l
l
l
l
S
SCREWED CONNECTIONS, MNPT
l
l
l
l
G
VICTAULIC CONNECTIONS (GROOVED)
l
l
l
l
F
l
l
l
l
l
FLANGED CONNECTIONS CODE OPEN
l
l
l
l
l
P
l
l
l
l
l
l
Example:
l
l
l
l
l
WCM7300E -
2
60 -
B
F
P
Epoxy
Choose one code selection from each option group to build model number and correct pricing. Notes: 1 - Consult Factory for temperature compensation factor.
1
=
WCM7300 - 260 - BFP
WCM 7300 E Insertion Probes
28.00 REF
11.45 REF
5.38 REF
8.10 REF
Often it is more economical to use an insertion probe than an inline on large diameter Flow Lines. Not only is the initial cost less, but handling costs in the field are also greatly reduced.
5.38 REF
Note: These dimensions are for the 2” probe. The 3” face to end would be 18” instead of 28”
www.fmcinvalco.com The specifications contained herein are subject to change without notice and any of said specifications should from the manufacturer that the specifications are currently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect. FMC INVALCO Fluid Control Stephenville, TX 76401, Phone: 254/968-2181, FAX: 254/968-5709, Toll Free: 800/468-2526 Printed in U.S.A. © 6/05 FMC INVALCO All rights reserved. 10 • SSIT042
Issue/Rev. 0.1 (2/04)
Net Oil Computer Specifications
Model 2100 Net Oil Computer
Energy Systems
Bulletin SSIS009 The INVALCO Model 2100 Net Oil Computer is used to determine net oil, net water, BS&W content, and net gas produced in a well test or similar operation.
Features 3 Meter Inputs Four Line 20 Character Alpha Numeric Display Jumper Selectable RS485 or RS232 Communication Option Four 10 amp SPDT Dry Relays One Megabyte of CMOS RAM Data Storage with Battery Backup.
Benefits Measure BS&W, Total Water, Total Oil, Total Gas Easy to Read - Even in Low Light Conditions Communicate Directly with SCADA System Control All Your Needed Accessories Retain All Important Data, Even if Power is Interrupted
Specifications Enclosure NEMA 4X fiberglass with clear hinged door. Inner metal door allows easy access to wiring terminals and s interface. Memory Battery backed RAM memory storage of setup and data values for 10 years. Power 110-220 VAC 50-60 Hz fused at 2 ampre 12 or 24 VDC fuse type Littlefuse @273002 Inputs Counts 3 - dry (16Hz maximum frequency) 3 - Pre-amp or photo pulser (10KHz maximum frequency) 3 - pickup coil (10KHz maximum frequency) (Any combination of the count inputs can be configured = 3 meter inputs total) Count Accuracy +/-0.25% of input counts per unit volume. Temperature 2 - dual thermistor probe inputs standard (LEMC #5507 probes) -20°F to 150°F standard +/-0.15°F Accuracy 1 - probe for emulsion stream temperature averaging. 1 - probe for gas stream temperature averaging. Optional higher temperature ranges available (32°F - 212°F or 60°F - 240°F)
Analog 1 - BS&W input scalable for 0-5 VDC, 1-5 VDC (0100%) 1 - BS&W input scalable 4-20mA (0-100%)
FMC Energy Systems 2526
!
Fluid Control
!
Stephenville, Texas 76401
Model 2100 Net Oil Computer
1 - Gas pressure input 1-5 VDC or 4-20mA Discrete 3 - Self powered dry closure inputs for external monitoring using Modbus Communication. 1 - Self powered dry closure input used as system reset integral with reset switch. Outputs 4 - relay NO or NC s 10 amp SPDT 3 - relays used for volume pulse output (Net or Gross-tenths of a barrel or cubic foot) 1 - relay for Alarm or Error indication/control 12 or 24 VDC output Serial Communication RS 232 three wire, or RS 485 five wire (Modbus RTU communication protocol) Interface Screen - 4 line by 20 character vacuum Florissant display. 4 - touch switches used to scroll through screens and change values 1 - toggle switch for reset FWD - (forward) - moves through displays in a forward direction. REV - (reverse) - moves through displays in a reverse direction UP - increases values on screens where interface is required DWN - (down) - decreases values or changes current option on screens where interface is required. Reset - resets totals. Optional external reset with dry using terminal block input where Reset switch is terminated also.
!
Telephone: 254/968-2181
!
FAX 254/968-5709
!
Toll Free: 800/468-
Model CX-545 Capacitance Probe & Model 4528-100-IL Detector
Measurement Accuracy ±1.0% Resolution/Sensitivity ±0.5% Probe Material A53 GrB Carbon Steel is standard. Stainless Steel available. Internal Probe Finish Baked-on phenolic two-part epoxy.
Model CX-545 Capacitance Probe & Model 4528 Detector-100-IL Model 4528-100-IL Detector for CX-545 Probe 0-100% - P513604
Features NACE Adaptable - Can be modified for use in sour service.
Detector/Probe Specifications Power Supply 12 Vdc @ 130 mA for 0-5 Vdc output. 24 Vdc required for 4-20 mA output. S&W Range 0-100%.
Probe Sizes/Length 2” I.D. is 17” face-to-face. 3” to 12” I.D. sizes are 32” face-to-face. Process Connections ANSI RF or RTJ Flanges to 600# (all sizes) (others by special order). Threaded MNPT or Grooved (2” and 3”). Pressure Ratings As per Flange selection, 1440 psig max. (Others by special order) NPT - 1440 psig max. Victualic grooved - 350 psig Temperature Range -20°F to 180°F standard. -20°F to 375°F optional.
Dimensions - CX-545 Specifications Inches (mm)
*
Size Dim A Dim B Weight (lbs) 2 INCH 17 (431 mm) 8.93" (227 mm) 20 3 INCH 17 (431 mm) 9.16" (233 mm) 40
*0°F to 180°F dimension given. For -20°F to 375°F dimension add 6.4”.
Note: Dimensions - Inches to the nearest tenth (millimeters to the nearest whole mm), each independently dimensioned from respective engineering drawings.
CX-545 Capacitance Probe Ordering Information CX-545 PROBE MATERIAL: Carbon Steel l CODE PROBE BODY SIZE - Consult Factory for larger sizes l 2 l 2 INCH I.D. x 17" FACE TO FACE 3 l 3 INCH I.D. x 32" FACE TO FACE 4 l 4 INCH I.D. X 17" FACE TO FACE CODE END CONNECTIONS l l 00 l l SCREWED ENDS (2" & 3" only) 00 l l GROOVED ENDS/Victaulic (2", 3" & 4" only) 00 l l 150 LB ANSI RAISED FACE 30 l l 300 LB ANSI RAISED FACE 60 l l 600 LB ANSI RAISED FACE 90 l l 900 LB ANSI RAISED FACE(SCH 80) 05 l l 150 LB ANSI RTJ 35 l l 300 LB ANSI RTJ 65 l l 600 LB ANSI RTJ 95 l l 900 LB ANSI RTJ (SCH 80) 115 l l 1500 LB ANSI RTJ (SCH 160) CODE MATERIAL AND TEMPERATURE OPTIONS l l l B l l l STANDARD MATERIALS, A53B CARBON STEEL, -20 - 180° F H l l l STANDARD MATERIALS/HIGH TEMP, -20 - 375° F S l l l 316 STAINLESS STEEL MATERIALS -20 - 180° F T l l l 316 STAINLESS STEEL/HIGH TEMP, -20 - 375°F CODE CONNECTION STYLE l l l l S l l l l SCREWED CONNECTIONS, MNPT G l l l l VICTAULIC CONNECTIONS (GROOVED) F l l l l FLANGED CONNECTIONS CODE OPEN l l l l l P l l l l l PHENOLIC COATING ( Interior ) l l l l l l Example: l l l l l CX - 545 3 60 B F P = CX-545-360-BFP Choose one code selection from each option group to build model number.
Three-Phase System with Three Meters
www.fmcinvalco.com The specifications contained herein are subject to change without notice and any of said specifications should from the manufacturer that the specifications are currently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect. FMC INVALCO Fluid Control Stephenville, TX 76401, Phone: 254/968-2181, FAX: 254/968-5709, Toll Free: 800/468-2526 Printed in U.S.A. © 6/04 FMC INVALCO All rights reserved. 14 • SSIT042
Issue/Rev. 0.1 (2/04)