8 METERS POLE FOR TENNIS COURT SUBMITTAL
PROJECT NAME: AL MESSILA RESORT & VIP SPA
CONSULTANT: DAR AL HANDASAH SUPPLIER: Power & Light Center Tel.: 44699360‐Fa x.:44690364‐E‐mail:
[email protected] REF.: PLC/FAÇADE/SUB‐0319/17 Date: 20/04/2017
Table of Contents
1. DATA SHEET 2. COUNTRY OF ORIGIN
1. DATA SHEET
C
76x4 THK
NOTES 1. FIRST ANGLE PROJECTION. 2. DIMENSION S SH OWN IN BRACKETS THUS (25) ARE REF. DIMEN SIONS ON LY.
75
2 ROWS OF 4 M10 BLACK NUTS WELDED OVER Ø12 HOLES IN SHAFT. TAP AFTER GALV TO SUIT STAINLESS STEEL GRUB SCREWS.
3. REMOVE AL L BURR S & SHARP EDGES. 4. DO N OT SCALE IF IN DOUBT ASK. 5. WEL DING SYMBOLS ARE TO BS EN ISO 40 63 & BS EN 2 2553 6. ALL STANDAR DS & SPEC IFICATIONS ARE TO BE TO THE LATEST REVISIONS. 7. FILL ET WELDS TO BE TO WEL D PROCEDU RE No. 031 W.
C 500
8. MATER IAL :PL ATE FROM M.S TO BSEN 100 25 GRD S355. PLATE 25mm THICK AND OVER TO BE CHARPY TEST VALUE OF 27 J (MIN) AT -20ºC. 9. FINISH HOT D IP GALV TO BS EN ISO 146 1. 10 SEE DRG NO C20 0/168 8/1 FOR SH AFT PRESSING D ETAILS. C201 /1 688 /2 FOR DOOR C OVER .
6
100 CLEAR DOOR OPENING
DC029A
A
20
525 BETWEEN BB LUGS BB051 FIT BBS11/510/90
EARTH LUG E.LUG
100
480
500 CLEAR DOOR OPENING
20
8000
6
600
A
BP002 FLANGE PLATE WELDED AS C201/22
190x4 THK
ITEM NO F101/FP/A3471 WEIGHT = 133KG
REV SIG © Copyright Abacus Lighting Ltd. All Rights Reserved.
THIS DESIGN AND ING
General tolerences unless stated otherwise:-
MUST NOT BE REPRODUCED. Patent No. Reg. Design No.
abooth
Checked
DOCUMENTS ARE THE SOLE PROPERTY OF ABACUS LIGHTING LIMITED AND
Drawn
0mm-500mm-------- ` 2 501mm-1000mm--- ` 5 Above----------------- ` 5
G SMITH
27/09/2012
DATE
DETAIL OF 8M OCTAGONAL COLUMN Client
Not to scale Date
DESCRIPTION
Title
Sales order No.
45943
Drg. No.
Power & Light Centre C200/1688
CHD
STANDARD COLUMNS
OCTAGONAL 4-12M OCTAGONAL STEEL Designed to EN40. Hot dip galvanised to BS EN1461:1999
Flange Plate Type 0
Column Dimensions
FA000G Bolts/cross brace M16 x 500mm FC020 Template
AFT Top Diameter
200mm
30mm x 20mm
280mm
12mm 100mm
Type 1
FA001G Bolts/cross brace M20 x 500mm FC021 Template
33mm x 25mm
H
200mm 290mm
15mm 100mm
Type 2
FA002G Bolts/cross brace M24 x 600mm FC022 Template
AFB Diameter at Ground Level
300mm
Ø30mm
500mm Cable Entry 150mm x 50mm
400mm
25mm
Ground Level Z Root Length
100mm
Accessories
ELSAB1/6A Single fuse cut-out, 6A, loop in/out (not fitted) ELSAB12/6A Twin fuse cut-out, 6A, loop in/out (not fitted)
Brackets
the Abacus sales office for details.
Root Mounted Dimensions (mm)
Product Code
Height
AFT
AFB
z
Door Opening
Weight (kg)
F041
4m
76
130
600
500x75
35
F051
5m
76
144
800
500x85
50
F061
6m
76
158
1000
500x85
64
F081
8m
76
183
1200
600x115
93
F101
10m
76
210
1500
600x115
129
F121
12m
76
232
1700
600x115
260
GD
Door Opening
Flange Plate
Weight (kg)
*Root concrete diameter based on poor soil or better, min. 230kN/m²
Flange Plate Mounted Dimensions (mm)
Product Code
Height
TD
F041/FP
4m
60
107
500x75
Type 0
33
F051/FP
5m
76
134
500x85
Type 0
49
F061/FP
6m
76
146
500x85
Type 1
60
F081/FP
8m
76
169
600x115
Type 2
84
F101/FP
10m
76
193
600x115
Type 2
112
F121/FP
12m
100
230
600x115
Type 2
282
30
www.abacuslighting.com
Flange Plate Mounting Abacus offers a choice of ive and non ive concrete foundations for fl ange plate mounting of lighting columns. By taking the OTM (overturning moment) from the column data matrix in the brochure, and identifying the correct ground pressure, the fully factored concrete foundation dimension can be determined from the tables below.
Projection (mm)
O.T.M (KNm)
Bearing Pressure (KNm)
A Width (mm)
B Depth (mm)
3M75
3
75
880
590
3M100
3
100
880
590
3M150
3
150
880
590
4M75
4
75
950
625
4M100
4
100
950
625
4M150
4
150
950
625
25
5M75
5
75
1050
675
50
5M100
5
100
1050
675
5
150
1050
675 700
Torque (Nm)
125
M16*500 Long Grade 4.6
125
M20*500 Long Grade 4.6
A non-ive foundation, where the ground pressure may be lower, takes no of the side forces and is therefore shallower but wider. Foundation
Holding down bolt projection & final torque values Bolt Size & Grade
Non-ive mass concrete foundation dimensions
M24*600 Long Grade 4.6
125
160
5M150
M30*800 Long Grade 4.6
150
310
6M75
6
75
1100
6M100
6
100
1100
700
6M150
6
150
1100
700
8M75
8
75
1150
725
8M100
8
100
1150
725
8M150
8
150
1150
725
10M75
10
75
1250
775
10M100
10
100
1250
775
10M150
10
150
1250
775
15M75
15
75
1400
850
15M100
15
100
1350
825
15M150
15
150
1350
825
20M75
20
75
1500
900
ive mass concrete foundation dimensions A ive foundation, where the ground pressure must be at least 150kN/m (or 1.5bar), takes into the side forces applied from the firmer ground. As a result, the concrete is typically narrower and deeper than non-ive. Foundation
O.T.M (KNm)
Bearing Pressure (KNm)
A Width (mm)
B Depth (mm)
3P150
3
150
650
750
20M100
20
100
1500
900
4P150
4
150
700
800
20M150
20
150
1500
900
5P150
5
150
750
800
30M75
30
75
1700
1000
6P150
6
150
750
900
30M100
30
100
1700
1000
8P150
8
150
850
950
30M150
30
150
1700
1000
10P150
10
150
900
950
40M75
40
75
1900
1100
15P150
15
150
950
1100
40M100
40
100
1800
1050
20P150
20
150
1050
1200
40M150
40
150
1800
1050
30P150
30
150
1200
1250
50M75
50
75
2100
1200
40P150
40
150
1250
1300
50M100
50
100
1900
1100
50P150
50
150
1350
1400
50M150
50
150
1900
1100
Soil pressure distribution ive concrete Typically used with good ground with ground bearing pressure of not less than 150KNm
Non-ive concrete Typically used with uniform or poor subsoil with ground bearing pressure of 75-150KNm
Typical section through foundation Bolt Projection
Template Temporary Cable Duct
B
Spacer Plate A Lower Template
■ Pressure distribution
■ Pressure distribution
Professional lighting systems to suit any project. Call 01623 518 333
45
2. COUNTRY OF ORIGIN